The RZ-UV2 series UV water sterilizer is an inline ultraviolet disinfection unit with a stainless steel reactor and 254 nm UVC lamps. Across 25 configurations, rated flow spans 0.5 to 1,980 GPM (0.113 to 450 m³/h), rated power 4 to 3,020 W, and G1/4A to DN250 connections. It treats water without chemical dosing for purified water, pharmaceutical, electronics, wastewater, swimming pool and landscape systems.
Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

Product Description

Overview of the RZ-UV2 Series UV Water Sterilizer

The RZ-UV2 series UV water sterilizer is an inline ultraviolet disinfection unit for industrial and commercial water circuits. Water enters through the inlet and passes a stainless steel reactor, where UVC lamps irradiate the flow at a 254 nm wavelength. The series lists 25 configurations, with rated flow from 0.5 to 1,980 GPM (0.113 to 450 m³/h), rated power from 4 to 3,020 W, and inlet/outlet connections from G1/4A to DN250. The units serve drinking purified water, electronics ultrapure water, pharmaceutical and biotechnology water, wastewater, swimming pool circuits and landscape water systems.

Industrial UV Sterilizer

Working Principle Behind the UV Water Disinfection System

UVC Action on Microorganisms

As water moves through the reactor, bacteria, viruses, parasites, algae and other pathogenic microorganisms receive a measured dose of UVC radiation. The radiation damages the deoxyribonucleic acid (DNA) and ribonucleic acid (RNA) in cell tissue through bond breakage and photochemical reactions, preventing the microorganisms from reproducing. Disinfection is completed without dosing chemical agents.

Treatment Without Added Chemicals

No chlorine, ozone or other reagents are added, so no reaction by-products are formed and the water composition, taste and odor remain unchanged. A 185 nm lamp configuration for TOC degradation is also part of the product family, along with chloramine and ozone decomposition functions for swimming pool and industrial water circuits.

Construction and Controls of the Stainless Steel UV Sterilizer

Reactor Chamber and Inlet/Outlet Connections

Each stainless steel UV sterilizer is built around a cylindrical reactor chamber with inline inlet and outlet ports, support feet for floor or skid mounting, and sealing caps at both ends. Quartz sleeves house the lamps and separate them from the water, while O-rings and waterproof cable glands maintain the seals. Compact configurations use threaded G1/4A to G1 1/2A ports, and higher-flow units use DN65 to DN250 flanged connections.

Lamp Types and Control Cabinet

Three lamp groups are listed: 254 nm standard lamps for the E05G to E44G UV water sterilizer models, 254 nm high-intensity lamps for the E15 to E80 UV water sterilizer models, and 254 nm amalgam lamps for the E180 to E450 UV water sterilizer models. The control cabinet provides lamp status indicators, power switching and metering. The RZUV-2300 monitor accumulates lamp running time and provides audible and visual lamp-fault alarms with dry-contact outputs.

Technical Specifications for the RZ-UV2 UV Water Sterilizer

Flow, Power and Lamp Configuration

No.

Model

Flow (GPM)

Flow (m³/h)

Rated Power (W)

Inlet/Outlet

Quartz Tube Length (mm)

Lamp Type

Outline Type

1

E05G

0.5

0.113

4

G1/4A

185

254 nm Standard Lamp

Type A

2

E1G

1

0.225

6

G1/2A

230

254 nm Standard Lamp

Type A

3

E3G

3

0.68

10

G1/2A

280

254 nm Standard Lamp

Type A

4

E6G

6

1.36

15

G3/4A

390

254 nm Standard Lamp

Type A

5

E9G

9

2

25

G3/4A

610

254 nm Standard Lamp

Type A

6

E13G

13

3

32

G1A

750

254 nm Standard Lamp

Type B

7

E22G

22

5

40

G1 1/2A

900

254 nm Standard Lamp

Type B

8

E44G

44

10

87

G1 1/2A

900

254 nm Standard Lamp

Type B

9

E15

66

15

180

DN65

900

254 nm High-Intensity Lamp

Type C

10

E25

110

25

300

DN80

900

254 nm High-Intensity Lamp

Type C

11

E40

176

40

390

DN100

900

254 nm High-Intensity Lamp

Type C

12

E50

220

50

480

DN100

900

254 nm High-Intensity Lamp

Type C

13

E60

264

60

570

DN125

900

254 nm High-Intensity Lamp

Type C

14

E80

352

80

660

DN125

900

254 nm High-Intensity Lamp

Type C

15

E90

396

90

770

DN150

920

Type D

16

E100

440

100

955

DN150

920

Type D

17

E125

550

125

1140

DN150

920

Type D

18

E150

660

150

1355

DN200

920

Type D

19

E180

792

180

1540

DN200

920

254 nm Amalgam Lamp

Type D

20

E200

880

200

1725

DN200

920

254 nm Amalgam Lamp

Type D

21

E250

1100

250

2085

DN200

920

254 nm Amalgam Lamp

Type D

22

E300

1320

300

2280

DN200

920

254 nm Amalgam Lamp

Type D

23

E350

1540

350

2465

DN250

920

254 nm Amalgam Lamp

Type D

24

E400

1760

400

2835

DN250

920

254 nm Amalgam Lamp

Type D

25

E450

1980

450

3020

DN250

920

254 nm Amalgam Lamp

Type D

UV Water Treatment Unit

Operating Conditions for the UV Water Treatment Unit

The operating manual specifies an ambient temperature of 5-40 ℃, relative humidity of 90% or below, water temperature of 5-60 ℃ and working pressure of 0.8 MPa or below. The power supply is 220V/50Hz. Units fitted with an automatic cleaning device require compressed air at 0.4-0.7 MPa. A heating and dehumidification option is offered for locations where relative humidity remains above 65% for long periods.

Cleaning and Maintenance of the UV Disinfection Unit

Manual and automatic cleaning configurations are available. Manual cleaning of quartz sleeves is scheduled at 0.5-2 year intervals depending on water quality, and a dedicated glass cleaning agent is specified. Routine checks cover the operating indicators, panel components, alarm status and leak points. Lamps are replaced at the end of rated life: 9,000 h (about one year) for low-pressure and low-pressure high-intensity lamps, and 13,000 h for low-pressure amalgam lamps. Power is disconnected before lamp replacement, and the reactor is drained before manual cleaning.

FAQ About the RZ-UV2 Series UV Water Sterilizer

Does the RZ-UV2 series UV water sterilizer use chemical additives?

No. The unit applies 254 nm UVC radiation that damages the DNA and RNA of microorganisms in the water flow. No chemical reagents are dosed and no reaction by-products are formed.

How long do the lamps in the UV water sterilizer last?

The low-pressure and low-pressure high-intensity lamps are rated at 9,000 h, about one year of operation. The low-pressure amalgam lamps are rated at 13,000 h. The control cabinet accumulates running time so replacement can be planned.

What flow rates and connections does the UV water sterilizer series cover?

Rated flow runs from 0.5 to 1,980 GPM (0.113 to 450 m³/h), with rated power from 4 to 3,020 W. Threaded ports run from G1/4A to G1 1/2A, and flanged connections from DN65 to DN250. The configuration tables list the values for every UV water sterilizer model.

Can a cleaning system be configured on the UV water sterilizer?

Yes. Manual cleaning configurations and automatic cylinder-driven cleaning configurations can be supplied. Automatic cleaning requires compressed air at 0.4-0.7 MPa, and manual cleaning intervals range from 0.5 to 2 years based on water quality.

Note: Parameters are for reference only; actual configuration and figures are subject to confirmation during order communication.

Previous: 
Next: 
Leave Us A Message

Subscribe to Our Email

Please leave your email address and we will contact you as soon as possible!

Quick Links

Products

Contact Us

 Telephone: +86-21-65424668
 Cellphone: +86-153-0166-9079
 WhatsApp: +1-725-242-9842
 Email:  yxmei@china-xiba.com
 Address: 5th Floor, Block B, Baishu Building, No. 1230 Zhongshan North 1st Road, Shanghai
Copyright © 2025 Shanghai Emperor of Cleaning Hi-Tech Co., Ltd. All Rights Reserved. Sitemap | Privacy Policy