ECH's fully automatic water softener adopts internationally renowned US FLECK and AUTOTROL automatic multi-port valves, together with JM multi-valve intelligent control system. It delivers professional water softening solutions for both industrial and civil scenarios, widely applied in boiler water supply, heating and refrigeration units, production process water, domestic hard water softening, reverse osmosis system pretreatment and more.
Technical Specifications
Model numbers | Flow Rate (T/h) | Exchange tanks quantities | Control operation mode |
ECH-R-1 ~ ECH-R-20 | 1/234/6/8/10/15/20 | 1 | single valve single tank |
ECH-RS-1~ ECH-RS-8 | 1/2/3/4/6/8 | 2 | single valve dual tank |
ECH-RS-10 ~ ECH-RS-50 | 10T*2/15T*2/20T*2/30T*2/50T*2 | 2 | double valve dual tank |
ECH-RS-10 ~ ECH-RS-50 | 10T/15T/20T/30T/50T | 2 | double valve dual tank |
Core Advantages
Stable Water Production & Wide Application Range
Full capacity coverage from 1T/H to 150T/H, with single-tank intermittent water supply and dual-tank 24-hour continuous water supply options
Direct model selection for raw water hardness ≤8mmol/L; customized secondary softening design available for raw water hardness over 8mmol/L
Effluent hardness stably maintained at ≤0.03mmol/L, effectively preventing scale formation and ensuring consistent qualified water quality
Ultra-low operating pressure loss of only 0.08Mpa, with no negative impact on existing pipe network efficiency
Fully Automatic Operation, Unattended & Worry-Free
Dual intelligent regeneration modes: time-controlled regeneration for stable water consumption; accurate flow (microcomputer) controlled regeneration for fluctuating water usage and poor raw water quality
Delayed dual interlock regeneration technology to avoid unnecessary regeneration and minimize manual intervention
Operates on standard AC220V power supply, with ultra-low running power consumption of only 3-40W
Application Fields
Industrial Field: Industrial boilers, heat exchangers, large central air conditioning systems, used to prevent scaling and corrosion, ensure stable operation of equipment and improve heat exchange efficiency.
Commercial & Catering Field: Hotels, restaurants, used to provide high-quality softened water for daily water use, laundry, catering and other links, improving service quality.
Manufacturing Field: Food industry, laundry printing and dyeing industry, used to ensure the quality of products (such as food processing, textile dyeing) and avoid the impact of hard water on production.
Medical Field: Medical institutions, providing clean and softened water for medical equipment cleaning, disinfection and other links, meeting medical hygiene standards.
Usage Methods & Safety Precautions
Usage Methods
Equipment Selection & Installation: Select the appropriate equipment model and configuration according to local raw water hardness, water consumption and use scenario. Install the equipment on a flat and firm foundation, ensure the inlet and outlet pipelines are connected correctly, and configure pipeline pumps if the inlet water pressure is lower than 0.2Mpa.
Parameter Setting: Set the regeneration mode (time control or flow control) according to water consumption regularity and raw water quality. Adjust related parameters to ensure the regeneration procedure operates automatically and stably.
Daily Operation: Check the salt level in the salt tank regularly and add salt in time to ensure the regeneration effect. The equipment operates automatically, no manual intervention is required in daily use.
Maintenance: Although no daily maintenance is needed, regularly inspect the controller, pipelines and joints for abnormalities (such as leakage, loose connections), and clean the resin tank and salt tank periodically to ensure long-term stable operation.
Safety Precautions
Ensure the inlet water pressure and working temperature are within the specified range to avoid equipment damage caused by excessive pressure or extreme temperature.
When adding salt to the salt tank, avoid spilling salt into the pipeline to prevent blockage; use clean, dry salt to ensure regeneration quality.
Operators should avoid direct contact with resin and salt water; wear protective gloves if necessary. In case of accidental contact with skin or eyes, rinse with plenty of clean water immediately.
Store the equipment in a well-ventilated, dry environment, away from direct sunlight, high temperature and corrosive substances.
Do not disassemble the controller, resin tank or other components without permission; contact professional technical personnel for maintenance and repair when abnormalities occur.
Keep the equipment out of the reach of children and unauthorized personnel to avoid accidental injury or misoperation.
FAQ
What models of water softeners do you offer?
We offer four main models to meet different water supply needs:
- Single valve single tank
- Single valve dual tank (one for use and another for backup)
- Dual valve dual tank (release water simultaneously)
- Dual valve dual tank (one for use and another for backup)
What brand of multi-port valve do you use?
We adopt high-quality, well-known brand multi-port valves that are durable, corrosion-resistant and have stable performance. These valves are specially selected for water softening equipment, ensuring smooth water flow control, reliable regeneration operation and long service life. Specific brand information can be provided according to your needs.
Can we customize the equipment?
Absolutely. We provide comprehensive customized solutions based on your actual needs. Customizable items include equipment model, resin tank capacity, salt tank size, regeneration control mode, inlet and outlet pipeline specifications, and other parameters, to perfectly match your raw water quality, water consumption and on-site installation conditions.
Is your company a trading company or a manufacturer?
We are a professional manufacturer with independent R&D, production and sales capabilities for water treatment equipment. We have mature production lines and technical teams, which can ensure stable product quality, on-time delivery and professional after-sales technical support, providing you with cost-effective products and one-stop service.
How to determine whether to use time control or flow control regeneration?
The selection of regeneration mode depends on your water consumption and raw water quality: if your water consumption is stable, time control regeneration is more suitable; if your water consumption is irregular and the raw water quality is poor, flow (microcomputer) control regeneration is recommended, which can adjust the regeneration cycle according to actual water consumption and water quality changes, ensuring optimal softening effect.
What should I do if the raw water hardness is higher than 8mmol/L?
When the raw water hardness is greater than 8mmol/L, we recommend using secondary softening. This method can further reduce the calcium and magnesium ion content in the water, ensuring that the softened water meets the use requirements and effectively preventing scaling of equipment and pipelines.